Dri-Flo 500 Performance System

Dry up to 12,000 bushels per day

What is a Shivvers Performance System?

Shivvers Performance Systems are a customizable package of components engineered to work together to provide optimum performance for drying grain, using continuous Counter-Flow technology.  Learn More

Dri-Flo performance systems can dry grain 24 hours a day 7 days a week.  As with other Performance Systems the Compudry Command Center automatically controls the drying process. You can continue to add wet grain as you harvest it.  The surge capacity of the Dri-Flo equals the size of your bin.

Shivvers’ Dri-Flo 500 Performance Systems use a bottom unload machine capable of removing up to 500 bushels per hour.  Two tapered sweep augers draw the grain to the middle of the bin, where it is it dropped into the horizontal transfer auger and carried to an available Jumpster transfer auger, air system, or elevator leg.

System Features

  • Horizontal unload machine with two tapered sweep augers
  • Surge capacity up to 13,100 bushels
  • Up to 12,000 bushels dried per day
  • Removal rates up to 500 bushels per hour
  • Fits bins 24’ to 42’ diameter

Download Full Line Brochure

Find A Dealer Request Information

More about this system

Performance Specs

SHIVVERS PERFORMANCE SYSTEM
Drying Capacities 
Circu-Lator 2 System Circu-Lator 2 High Torque Circu-Lator 3 Systems
& Dri-Flo 500 System  & Dri-Flo 1000 Systems & Dri-Flo 1500 Systems
Shown by Green: Shown by Yellow: Shown by Red:
Moisture 24' Dia. S.P. 27' Dia. S.P. 30' Dia. S.P. 33' Dia. S.P. 36' DIA. S.P. 42' Dia. S.P. 48' Dia. S.P. Qty Blue Flame Fans and Heaters
Removal BU/DAY BU/DAY BU/DAY BU/DAY BU/DAY BU/DAY BU/DAY
5% 6,200 3.4" 6,800 2.7" 7,200 2.2" 7,600 1.8" One 13 HP Blue Flame
10% 3,400 3.4" 3,700 2.7" 3,900 2.2" 4,100 1.8" 3.7M BTU Axial
5% 8,100 5.1" 8,800 4.1" 9,400 3.3" 9,800 2.6" One 13 HP Blue Flame
10% 4,400 5.1" 4,800 4.1" 5,100 3.3" 5,400 2.6" with Turbo Booster
5% 9,700 4.6" 11,000 4.1" 12,100 3.6" 13,000 3.1" Two 13 HP Blue Flame
10% 5,200 4.6" 5,900 4.1" 6,500 3.6" 7,000 3.1" 3.7M BTU Axial
5% 11,400 8.5" 13,100 7.3" 14,600 6.3" 15,900 5.4" 17,000 4.6" 18,700 3.3" 19,900 2.5" Two 13 HP Blue Flame
10% 6,300 8.5" 7,200 7.3" 8,000 6.3" 8,700 5.4" 9,300 4.6" 10,200 3.3" 10,900 2.5" with Turbo Booster
5% 14,500 4.7" 16,100 4.2" 18,800 3.4" 20,700 2.6" Three 13 HP Blue Flame
10% 7,800 4.7" 8,700 4.2" 10,100 3.4" 11,100 2.6" 3.7M BTU Axial
5% 17,600 8.3" 19,600 7.4" 21,500 6.5" 24,600 5" 27,000 3.9" Three 13 HP Blue Flame
10% 9,500 8.3" 10,500 7.4" 11,500 6.5" 13,200 5" 14,500 3.9" with Turbo Booster
5% 7,200 4.3" 7,700 3.3" 8,000 2.6" 8,200 2" One 15 HP C-Fan 
10% 3,900 4.3" 4,100 3.3" 4,300 2.6" 4,400 2" w/Blue Flame II Heater
5% 13,200 5.4" 14,300 4.6" 15,000 3.8" Two 15 HP C-Fan 
10% 7,100 5.4" 7,700 4.6" 8,000 3.8" w/Blue Flame II Heater
5% 22,000 4.2" 23,400 3.1" Three 15 HP C-Fan 
10% 11,800 4.2" 12,600 3.1" w/Blue Flame II Heater
5% 8,300 5.3" 8,900 4.1" 9,300 3.2" 9,600 2.5" One 20 HP C-Fan
10% 4,500 5.3" 4,800 4.1" 5,000 3.2" 5,100 2.5" w/Blue Flame II Heater
5% 16,300 5.6" 17,300 4.7" 18,500 3.3" 19,200 2.3" Two 20 HP C-Fan
10% 8,800 5.6" 9,300 4.7" 10,000 3.3" 10,300 2.3" w/Blue Flame II Heater
5% 25,200 5.2" 27,100 3.9" Three 20 HP C-Fan
10% 13,500 5.2" 14,600 3.9" w/Blue Flame II Heater
5% 11,600 6.1" 12,300 4.9" 12,900 3.9" 13,400 3.2" One 30 HP Airmaxx Dbl. Inlet C-Fan 
10% 6,200 6.1" 6,600 4.9" 6,900 3.9" 7,200 3.2" w/ 7,400,000 BTU Heater
5% 22,200 6.8" 24,500 5" 26,100 3.7" Two 30 HP Airmaxx Dbl. Inlet C-Fan 
10% 11,900 6.8" 13,200 5" 14,000 3.7" w/ 7,400,000 BTU Heater
5% 14,200 6" 14,800 4.8" 15,200 3.9" 15,800 2.6" 16,100 1.8" One 40 HP Airmaxx Dbl. Inlet C-Fan 
10% 7,600 6" 7,900 4.8" 8,200 3.9" 8,500 2.6" 8,600 1.8" w/ 7,400,000 BTU Heater
5% 28,200 6.1" 29,800 4.5" Two 40 HP Airmaxx Dbl. Inlet C-Fan 
10% 15,200 6.1" 16,000 4.5" w/ 7,400,000 BTU Heater
5% 17,100 6" 17,800 4.9" 18,700 3.3" 19,200 2.3" One 50 HP Airmaxx Dbl. Inlet C-Fan 
10% 9,200 6" 9,600 4.9" 10,000 3.3" 10,300 2.3" w/ 7,400,000 BTU Heater
5% 35,000 5.6" Two: 50 HP Airmaxx Dbl. Inlet C-Fan 
10% 18,700 5.6" w/ 7,400,000 BTU Heater
Capacities are based on yellow corn dried under conditions of 50˚F Ambient, 70% Relative Humidity, Drying temperature at 180˚F  at Static Pressure (SP) indicated,
 estimated Grain depth 6' with 1 1/2 pts removed in slow cooling process.  Specifications shown with LP, use of NG may make results vary.

Find A Dealer Request Information

Talk to a dealer or request information to find out how you can improve your operation.